UPILEX-S - Ube ultra-High Heat-Resistant Polyimide Film

UPILEX, the ultra-high heat-resistant polymide film, is the product of the polycondensation reaction between biphenyltetracarboxylic dianhydride (BPDA), of which porcess Ube Industries originally developed, and diamine. Thanks to its outstanding characteristics over a wide temperature range, UPILEX has been the subject of much attention as a new material for use in the electronics and other leading-edge industries. Most notable of these characteristics is UPILEX's unbeatable physical, mechanical, electrical, and chemical properties under high-temperature conditions. In each of these areas, UPILEX is far superior to the competition, as an ultra-high heat-resistant polyimide film that will continue to fulfill the strictest requirements.


Mechanical Properties
As mentioned previously, UPILEX-S demonstrates outstanding mechanical characteristics through a wide temperature range. UPILEX-S displays high tensile strength and modulus, and also features outstanding long-term heat resistance. Another advantage inherent in UPILEX-S is its high resistance to hydrolysis, as its properties are practically unaffected, even by immersion in boiling water for long periods of time.

Table-1 Mechanical Properties
Properties Unit Typical Values Test Method
UPILEX-25S(25µm)UPILEX-75S(75µm)
-269°C -196°C 25°C 300°C 25°C 200°C
Tensile Strength (MD) MPa 735 647 520 290 360 270 ASTM D882
Stress at 5% Elongation (MD) MPa --- --- 260 90 210 110 ASTM D882
Elongation (MD) % 10 15 42 67 50 80 ASTM D882
Tensile Modulus (MD) MPa --- --- 9100 3700 6900 3800 ASTM D882
Tear Strength-Initiation [Graves] (MD) N --- --- 230 --- 290 --- ASTM D1004
Tear Strength-Ipropagation [Elmendorf] (MD) N --- --- 3.2 --- 4.2 --- ASTM D1922
Folding endurance [MIT] Cycles --- --- >100,000 --- >25,000 --- ASTM D2176
Density X 103kg/m3 --- --- 1.47 --- 1.47 --- ASTM D1505
Coefficient of Kinetic Friction (film-to-film) --- --- --- 0.4 --- 0.4 --- ASTM D1894
*MD: Machine Direction








Electrical properties
UPILEX-S exhibits excellent electrical characteristics over a wide range of temperatures and frequences. Even at high temperatures, UPILEX-S shows remarkably slight deterioration in its electrical properties.

Table-2 electrical Properties
PropertiesUnitTypical ValuesTest conditionsTest Method
UPILEX-25SUPILEX-75S
25°C200°C25°C200°C
Dielectric StrengthkV6.86.8111150HzASTM D149
Dielectric Constant---3.53.33.33.2103 HzASTM D150
Dissipation Factor---0.00130.00780.00380.0056103 HzASTM D150
Volume Resistivity Ω - m 1015 101310141014DC100VASTM D257
Surface ResistivityΩ>10171015>10161015DC100VASTM D257




Thermal Properties
UPILEX-S boasts the highest heat resistance of any plastic film currently available. Its major features include smaller values in both heat shrinkage and thermal linear expansion coefficients, and self-extinguishing (UL94 VTM-0). This makes it ideal for use in FPC and TAB-tape substrates composed of mninute circuits.

Table-3 Thermal Properties
Properties Typical Values Test Conditions (Test Method)
UPILEX-25S UPILEX-75S
Heat shrinkage (%) 0.1 0.01
200°C, 2HoursASTM D1204
Thermal Linear Expansion Coeficient (ppm/K) 20 - 200°C 12 20 Values determined by minute linear expansion tester at 5°C/min. temperature increments
Melting Point (°C) None  
Specific Heat kJ(kg·K) 1.13
Differential ScanningCalorimeter
Temperature Index (°C) 290 Heat Treatment: 20,000Hours
Flammability UL94 VTM-0 (Exceeding 7.5µm) UL94 File No.48133
Oxygen Index (%) 66 JIS K7201
Thermal Conductivity (W/(m·K) 0.290 Laser Flash Method









Chemical-Resistant Properties
UPILEX-S is insoluble in all organic soluvents, and is sufficiently resistant to virtually any chemicals, including inorganic acid and alkali solution and so forth. UPILEX-S retains its pysical properties and superior dimensional stability even when exposed to chemicals.

Table 4-1 Chemical Properties

Properties Typical Values [25µm Film] (%) Test Conditions Test Method
Strength Retained Elongation Retained Modulus Retained
Resistanceto:
10% Sodium Hydroxide
Glatial AceticAcid
WaterPH=1.0
PH=4.2
PH=8.9
PH=10.0
 
80
100
95
95
95
95
 
60
95
85
85
85
85
 
95
100
100
100
100
100
 
Immersion at25°Cfor 5 days
Immersion at110°Cfor 5 weeks
Immersion at100°Cfor 2 weeks
Immersion at100°Cfor 2 weeks
Immersion at100°Cfor 2 weeks
Immersion at100°Cfor 4 days
ASTM D882
Water Absorption
1.4%
0.8%
Immersion inwater at 23°C for 24 hours
Equilibrium at60%RH, 50°C
ASTM D570
Gas Permeability
Water Vapor
Oxygen
Carbon Dioxide
 
1.7X10-3kg/m2/25µm
0.8X10-6m3/m2/25µm
1.2X10-3m3/m2/25µm
   
At 38°C, 90%RH for 24 Hours
At 30°C, 1 atm for 24 Hours
 
ASTM E96
ASTMD1434


Table 4-2 Dimensional Stability WhenImmersed in Various Chemical Solutions and Solvents .(Unit:%)

Chemicals Typical Values [25µm Film] Immersion Conditions
MD TD
Ferric Chloride (37%) - 0.01 +0.01 At room Temperature for 10 minutes
Cupric Chloride (37%) +0.01 - 0.01 At room Temperature for 10 minutes
5% Sodium Hydroxide - 0.02 +0.03 At 60°C for 30 minutes
Isopropanol - 0.00 +0.01 At room Temperature for 10 minutes
Methyl Ethyl Ketone - 0.01 - 0.00 At room Temperature for 10 minutes
Methylene Chloride/Trichloroethane(Mixed) - 0.00 +0.00 At room Temperature for 10 minutes
2N-Hydrochloric Acid - 0.00 - 0.00 At room Temperature for 10 minutes
*MD = Machine Direction
TD = Transverse Direction




Environmental Resistance

UPILEX-S features low water absorption and hygroscopic expansion. another advantage inherent in UPILEX-S is its low absorption/desorption speeds and superior weather resistance.







General Properties of Various Heat Resistant Films
Properties
Unit
UPILEX-S
Conventional
Polymide
Polyester
Polysulfone
Polytetrafluooethylene
Density
g/cm3
1.47
1.42
1.38 - 1.41
1.24 - 1.25 2.1 - 2.2
Tensile Strength
MPa
520
173
137 - 245
58 - 74 11 - 31
Elongation
%
42
70
60 - 170
60 - 110 100 - 400
Tensile Modulus
MPa
9120
2961
---
--- ---
Tear Strength-Initiation (Graves)
N
226
197
177 - 530
39 ---
Tear Strength-Propagation
N
3.24
3.14
4.90 - 10.79
3.92 - 4.90 3.92
Resistance to Organic Solvents
---
Excellent
Excellent
Excellent
Excellent Excellent
Resistance to Strond Acids
---
Good
Good
Good Excellent Excellent
Resistance to Strong Alkalis
---
Good
Inferior
Good Excellent Excellent
Dielectric Constant
---
3.5
3.5
3.2
3.1 2.1
Dissipation Factor
---
0.0013
0.003
0.005
0.0008 0.0002


UPILEX-S Grades and Area Factors
Type Grade Thickness (µm) Width (mm) Area Factor (m2/kg)
UPILEX-S
7.5SN 7.5 508/1016 90.4
12.5SN 12.5 508/1016 54.4
25S 25 508/1016 27.2
50S 50 508/1016 13.6
75S 75 508/1016 9.1
125S 125 508/1016 5.4


1. Statement Content

The statement content is based on materials, data and informationcurrently available and no guarantee is made with regard to content, physical properties or hazards and harmful effects. Furthermore, as handing precautions relate to normal handling, in cases of special handling, safety measures appropriate to the application and its method should ba taken.

2. Handling Precaustions

- When handling UPILEX-S at high temperatures attention should be paid to ventilation. This is because DMAC, of which UPILEX-S contains traces, produces carbon monoxide at temperatures greater thatn 300°C and at high temperatures, in excess of 500°C, UPILEX-S generates pyrolytic products. Ventilation should be adequate to ensure that concentrations of DMAC and carbon monoxide are kept to safe levels(10ppm and 100ppm). In addition, breathing safety equipment, such as organic gasmasks, should be used to prevent the inhalation of fumes.

- As data relating to health and the natural environment are incomplete, the greatest caution should be exercised when handling UPILEX-S.

- When disposing of UPILEX-S, the material should be burned in an appropriate incinerator as there is concern about environmental pollution. This should be done in accordance with atmospheric pollution prevention laws.

- Please read the material safety data sheet(MSDS) before use. If you have not received a MSDS, please request one from the company.

3. Fire Measures

Fires should be extinguished with powder, carbon dioxide, foam fire exinguishers or water sprays.

4. emergency measures

- If UPILEX-S enters the eye, particles should be flushed out thoroughly and immediately with clean water. If the eye becomes bloodshot or exhibits any other abnormality, medical assistance should be sought.

- In case of contact with the skin, the affected area should be washed with soap and large quantities of water. If irritation persists, medical advice should be sought.

- If swallowed, induce vomiting, wash the mouth and seek medical attention.






 